Multi functional operator instrument

Có thể đàm phánCập nhật vào05/18
Mô hình
Thiên nhiên của nhà sản xuất
Nhà sản xuất
Danh mục sản phẩm
Nơi xuất xứ

Tổng quan

Multi functional operator instrument, used as a supporting product for PID regulators or DCS systems, for manual adjustment or as a backup instrument. The output signal is a current and voltage signal with positive and negative effects. One way to regulate input signals, used to receive signals transmitted from PID regulators or DCS systems. Can be connected with DC current and DC voltage. The main display window displays the operation output values, and the secondary display window can display the adjustment input signals, operation output values, or manual/automatic status through parameter selection. Welcome to consult with all users.

Chi tiết sản phẩm

Multi functional operator instrumentAs a supporting product for PID regulators or DCS systems, it is used for manual adjustment or as a backup instrument. The output signal is a current and voltage signal with positive and negative effects. One way to regulate input signals, used to receive signals transmitted from PID regulators or DCS systems. Can be connected with DC current and DC voltage. The main display window displays the operation output values, and the secondary display window can display the adjustment input signals, operation output values, or manual/automatic status through parameter selection. Welcome to consult with all users.


Multi functional operator instrumentProduct Introduction

Intelligent operation instrument,As a supporting product for PID regulators or DCS systems, it is used for manual adjustment or as a backup instrument. The output signal is a current and voltage signal with positive and negative effects.
One way to regulate input signals, used to receive signals transmitted from PID regulators or DCS systems. Can be connected with DC current and DC voltage.
The main display window displays the operation output value, and the auxiliary display window can display the adjustment input signal, operation output value, or manual/automatic status through parameter selection.
■ Signal output can be directly operated through button operation. The operation output has upper and lower limit limiting functions.
Optional 1-2 alarm output function.
Optional 1-point manual/automatic status signal output function.
Optional 1-point external signal input for switching between manual/automatic modes.
■ Optional tracking/transmission output function.
Optional communication interface for reading data.

Basic specifications

project

specification

power supply voltage

ACpower supply

100~240 V AC 50/60 Hz

AC/DCpower supply

10~24V AC 50/60 Hz10~24V DC

power consumption

ACpower supply

7 VAbelow

AC/DCpower supply

AC6 VAfollowing;DC5Wbelow

Allowable voltage variation range

The voltage of the power supply90%~110%

insulation resistance

100500V DC MEGABenchmark)

insulation strength

2000V AC (Test conditions:50/60Hz1Minutes)

anti-interference

IEC61000-4-2(Electrostatic discharge))Grade III

IEC61000-4-4(Electric Fast Transient Pulse Group), Level III

IEC61000-4-5(Surge), Level III

Protection level

IP65(Product front panel protection)(GB/T42-2008

runtime environment

ambient temperature

-30~60(Save:-40~65

ambient humidity

35~85 %RHNo condensation

Installation location

Indoor, height<2000m

■ Enter specifications

project

specification

Measure and control speed

0.1second

basic error

±0.2 %FS

display range

-1999~9999

Display specifications

double4bitLEDDisplay (Main Display Window)+Second display window)

Æ Note:Please refer to the input signal type description for details Input signal and display explain.

Operation output specifications

project

specification

Q1

current output(4~20)mAThe(0~10)mAThe(0~20)mA

Photoelectric isolation,

Resolution:1/10000Load capacity:600Ω

Q2

voltage output(0~5)VThe(1~5)V

Q3

Voltage output(0-10V

■ Optional specifications

project

specification

alarm

output

160×80size

T1~T2

1~2The output of the alarm relay is normally open+Normally closed dual contacts

250V AC/3A

resistive load

96×96size

T1~T2

1~2Point alarm relay output, all with normally open contacts

96×48size

T1~T2

1~2Point alarm relay output, all with normally open contacts

track/transmitter output

A1

current output(4~20)mAThe(0~10)mAThe(0~20)mA

Photoelectric isolation,

Resolution:1/10000Load capacity:600Ω

A2

voltage output(0~5)VThe(1~5)V

A3

Voltage output(0-10V

communication

interface

MS1

RS232interface

Photoelectric isolation,

Response time: less than500μS(Measurement value)

Communication protocol selected through software
TCASCIIorModbus-RTU

MS2

RS485interface

Status signal output

D

1Point relay output, normally open contact,250V AC/3A, resistive load

External signal input

K

1Point externalPassive contact switch signal, used forControl hand/Auto Status







Æ note*The optional specifications only describe the functions of the instrument selection. For detailed guidance on selecting instrument models, please refer to the instrument selection sample.